You are not familiar with the introduction of windows7 remote desktop - mstsc

  
                

When a computer turns on the remote desktop connection function, we can control this computer at the other end of the network and operate the computer in real time through the remote desktop function. This is a function that many people know, but you know the windows7 system. By default, the server is at the same time, you can open the remote desktop, two "virtual desktop (MSTSC command open)" and "real desktop (mstsc /console parameters open), open the window, can not see each other To.

If you want to see other desktop connections, you can open the Task Manager, view the user connections, select the connection, and you can choose to view the correct connection.

Remote Desktop mstsc /console is connected to session 0, MSTSC opens a virtual session, which is equivalent to the computer login again. That is to say, with the console parameter connected is the display of the "real desktop", usually many times you need to use mstsc /console to open "rdreal desktop" to view all application windows, or use other remote tools connection is visible Such as pcanywhere VNC.

Problem 1: More than the maximum number of connections are on the server.

In addition to restarting the server, the best way to do this is to log in using the /console (console mode mstsc /console /V: IP: terminal port). Mstsc /console /V: 192.168. *:25000

Question 2: Windows XP upgrade to SP3 can't use mstsc /console to connect to console

Upgrade to Windows XP SP3 command replace MSTSC /administrator can implement XP2 mstsc /Console features.

Tip: Regardless of which version of Microsoft's operating system you are using, if you have forgotten the MSTSC detailed parameters, you can use MSTSC in CMD to help you see the specific usage.

Copyright © Windows knowledge All Rights Reserved